TRACKER by Global Solutions – Transient Voltage Surge Suppressors (TVSS), Appointed Dealer in Vismin area. Protection devices for high electrical surges in the form of spikes and lightning. (USA)
Surge Protection Device TL Series
Our full featured SPD that incorporates high-energy MOVs with the best performing AC filter on the market to provide protection against externally and internally generated transients and noise.
Design Features:
- ANSI/IEEE C62.41 Location C, & B
- SPD according to IEC 61643-1 Class I, II
- Ideal for mounting next to switchgear, MCCs,distribution panels, and branch panels
- High energy fail-safe parallel hybrid designwith component level fusing● Solid-state bi-directional protection
Performance:
● Surge currents per phase (Imax): 120, 160, 200, 250, 320, and 400kA
● Nominal discharge surge current In: 60, 80, 100, 125, 160, and 2000kA
● Regulatory Listings: UL 3rd Edition Certified, Type 1 & Type 2 SPD; CE Marked
● All mode protection: L-G. L-N, N-G, L-L
● 200kAIC fault current rating
● Green LED fault indicators for each phase
● Form C dry relay contacts NC & NO
● Response time: Less than .05 nanoseconds
● Life Cycle Tested: 5,000 Cat. C3 High Exposure Impulses with ≤ 10% degradation
● Operating frequency: 47-400Hz; Operating temperature: -40C to +70C
● Advanced EMI Filter frequency range: -45dB at 3kHz to 1MHz
● Enclosure: NEMA 12 (IP52); Painted Steel
● Pre-wired with #10AWG leads● Size: -11.5 x 8 x 6 (292x203x157.5mm); Weight: 15lbs/7.5kg
Brochure Download
TRACKER - Surge Protection Device TL Series
Surge Protection Device TM Series
Design Features:
● ANSI/IEEE C62.41 Location C, B, & A.
● Ideal for mounting next to single phase
panelboards and critical loads
● Individually fused MOV technology
●Solid-state protection technology
Performance:
● Surge currents per phase: 80, 100, 120, 160, 200kA
● Regulatory Listings: UL 3rd Edition Certified, Type 2 SPD; CE Marked
● Discrete modes of protection L-G, L-N, N-G where applicable
● Real time diagnostics include LED fault Indicators
● Response time: Less than .5 nanoseconds
● Third party tested to survive 3,000 C3 6kV/3kA
● Operating frequency: 47-400Hz; Operating temperature: -40C to +65C
● Enclosure: (80Ka model only) 4 x 4 x 2 (10x10x5cn); Die cast aluminum; NEMA 3R (IP22);
(100kA + models) 7.5 x 5.43 x 4.75 (19 x14x12cn); Fiberglass; NEMA 12 (IP55)
Impact resistance; Non-corrosive; Dust tight
Weight: (80kA) 4lbs/1.8kg; (100kA+) 10lbs/4.5kg
● Pre-wired with #10AWG leads
Brochure Download
TRACKER - Surge Protection Device TM Series
Surge Protection Device TN Series
SPD designed for UL 1449 Third Edition &
CE Listed
Design Features:
- ANSI/IEEE C62.41 Location C, B, & A.
- Ideal for mounting next to switchgear, MCC, distribution panels, branch panels and critical loads
- High energy fail-safe parallel hybrid design
- Solid-state bi-directional protection technology
Performance:
● Surge currents per phase: 60, 80, 100, 120
● Regulatory Listings: UL 3rd Edition Certified, Type 2 SPD; CE Marked
● All mode protection L-G. L-N, N-G, L-L where applicable
● 4 Discrete modes of protection L-N, N-G
● LED Indicators per phase
● Response time: Less than .5 nanoseconds
● Life Cycle Tested: 3,000 Cat. C3 High Exposure Impulses with ≤ 10% degradation
● Operating frequency: 47-400Hz; Operating temperature: -40C to +70C
● Enclosure: NEMA 4X (IP56); UL94-5V; Fiberglass reinforced polyester;
Non-corrosive; Water resistant; Dust tight; Impact resistance
● Pre-wired with #10AWG leads● Size: 7.5 x 5.5 x 4.75 (19 x14x12cn); Weight: 10lbs/4.5kg
Brochure Download
TRACKER - Surge Protection Device TN Series
Surge Protection Device TR Series
The Next Generation SPD designed for UL
1449 3rd Edition; IEC; CE Listed
Design Features:
- ANSI/IEEE C62.41 Location C, B, & A.
- SPD according to IEC 61643-11 Type 2
- SPD according to IEC 61643-1 Class I, II, III
- Ideal for mounting next to switchgear, MCC, Distribution panels, branch panels and critical
- High energy fail-safe parallel hybrid design with component level fusing
- Solid-state bi-directional protection technology
Performance:
● Surge currents per phase (Imax): 60, 80, 100, 120, 160, 200kA
● Nominal discharge surge current In: 30, 40, 50, 60, 80, 100kA
● Regulatory Listings: UL 3rd Edition Certified, Type 2 SPD; CE Marked
● All mode protection L-G. L-N, N-G, L-L
● LED Indicators per phase
● Response time: Less than .5 nanoseconds
● Life Cycle Tested: 5,000 Cat. C3 High Exposure Impulses with ≤ 10% degradation
● Operating frequency: 47-400Hz; Operating temperature: -40C to +70C
● EMI Filter frequency range: 1000 Hz to 1 Meg Hz -40dB or greater
● Enclosure: NEMA 4X (IP56); UL94-5V; Fiberglass reinforced polyester;
Non-corrosive; Water resistant; Dust tight; Impact resistance
● Pre-wired with #10AWG leads● Size: 7.5 x 5.5 x 4.75 (19 x14x12cn); Weight: 10lbs/4.5kg
Brochure Download
TRACKER - Surge Protection Device TR Series
COMTRACK CAT55E
GENERAL SPECIFICATIONS
Applications: Data systems with <1Gbps and <100MHz
(For systems that are <10Mbps use SLP Series)
Design: Solid State fail-safe design
ELECTRICAL SPECIFICATIONS
Strength: TK-CT2-CAT5E: 3000 Watts per wire
TK-CT2-CAT5E-POE: 20000 Watts per wire
Wires Protected: All wires.
Response Time: < 1 nanosecond
Number of Protected Pairs (Wires): 4 Pair (8 wire)
MECHANICAL SPECIFICATIONS
Dimensions (approx): 4.375”H x 2.885”W x 1.230”D
Enclosure Type: High-impact, non-metallic UL 94-5V
flame resistant rated
Connection Method: RJ45 In/Out (RJ45 female connections
on both sides)
Mounting Method: All units come standard with a universal
mounting bracket that allows the units to be screw
or Din-Rail mounted (horizontally or vertically).
Operating Temperature: -40° C to 85° C (-40° F to
185° F)
Weight: 0.75 lbs. (0.34 kg)
Brochure Download
Comtrack_cat5e_poe.pdfw
LoadTrack
GENERAL SPECIFICATIONS
Maximum Rated Surge Current: 40kA per phase
Application: ANSI.IEEE C62.41 Location C, B & A
Design: Ultra compact, fail-safe design with dual component-
level fusing
Safety Listing: ETL recognized component under UL
1449 3rd Edition as a type 4 SPD, cETL, and under UL
1283 as an electromagnetic filter.
ELECTRICAL SPECIFICATIONS
Input Power Frequency: 47-64Hz
Maximum Continuous Operating Current: 30 amps
Modes of Discrete Suppression Circuitry:
All modes L-N, L-G & N-G
Response Time: < 1 nanosecond
Standard Monitoring: Status indicating light
Short Circuit Current Rating: 100kAIC short circuit
current rating with a 30 amp max Class T fuse
MECHANICAL SPECIFICATIONS
Dimensions: 3.94”H x 2.80”W x 2.28”D
Enclosure: ABS Plastic UL94-5VA
Connection Method: Hard-wired via box terminals
#22AWG - #14 AWG
Mounting Method: Screw down or Din-Rail mounted.
Operating Temperature: -40° C to 70° C (-40° F to
160° F)
Weight: 1.00 lbs. (0.45 kg)
Brochure Download
TRACKER - TE 30A
TRACKER - TK-LT 250-15